Design & Calculation
Technical Engineering & Calculations
Contract Engineering & Capacity Extension
We identify risks early, keep interfaces clean and think ahead from the first drawing to the last weld – so your project stays on schedule.

Your team is at full capacity – but the next project won't wait. Whether it's a peak in workload, a shortage of skilled engineers, or a project outside your core expertise: we step in where you need capacity. As an extension of your engineering team, we take over the design work according to your specifications – from 3D modelling to production-ready 2D drawings.
No onboarding effort, no permanent hire, no compromise on quality. You stay in control, we deliver the work.
REFERENCES
Vacuum Drain Tank
Key Facts
Location:Libya
Code:ASME SEC.VIII.DIV.1
Medium:Light Distillate Oil
Design Temperature:85 °C
Design Pressure:1 barg
Total Volume:3.5 m³
Primary and Secondary Pipe Supports
Key Facts
Code:EN 13480
Scope:3D Design – Piping and Supports, Isometric Drawings & BoM

Vacuum Drain Tank
Key Facts
Location:Iraq
Code: ASME SEC.VIII.DIV.1
Medium:Demin Water + Corrosion Inhibitor
Design Temperature:400 °C
Design Pressure: full vacuum / 3.5 barg
Total Volume:5.6 m³
Primary and Secondary Pipe Supports
Key Facts
Location:Turkey
Code:GOST
Scope:Manufacturing Drawings, Technical Specifications
Quantity:375 t
Glycol Mixture Tank
Key Facts
Location:Uzbekistan
Code:ASME SEC.VIII.DIV.1
Medium:Glycol Mixture
Design Temperature:100 °C
Design Pressure:0 barg
Total Volume:8.5 m³
Corrosion Inhibitor Feeder
Key Facts
Location:Iraq
Code:ASME SEC.VIII.DIV.1
Medium:Corrosion
Inhibitor
Design Temperature: 80 °C
Design Pressure:3.5 barg
Total Volume:20 l
Atm Drain Tank
Key Facts
Location:Iraq
Code:ASME SEC.VIII.DIV.1
Medium:Demin
Water + Corrosion Inhibitor
Design Temperature:400 °C
Design Pressure:3.5 barg
Total Volume:5.6 m³
CCW EXPANSION TANK
Key Facts
Location:Iraq
Code:ASME SEC.VIII.DIV.1
Medium:Demi Water + corrosion inhibitor
Design Temperature:85 °C
Design Pressure: 3.5 barg
Total Volume:5 m³
Atmospheric Flash Tank
Key Facts
Location:Senegal
Code:ASME SEC.VIII.DIV.1
Medium:Air
Design Temperature:350 °C
Design Pressure:3.5 barg
Total Volume:2.5 m³
Glycol Drain Pot
Key Facts
Location:Uzbekistan
Code:ASME SEC.VIII.DIV.1
Medium:Glycol Mixture
Design Temperature:100 °C
Design Pressure:2 barg
Total Volume:0.65 m³
Hydrogen Storage Tank
Key Facts
Location:Libya
Code:ASME BPVC SEC.VIII.DIV.1
Medium:Hydrogen
Design Temperature:80 °C
Design Pressure:41.5 barg
Total Volume:100 m³